Human CLEC4M(C-type lectin domain family 4 member M) ELISA Kit

Category:

This kit is based on Double antibody-Sandwich ELISA detection method and takes 4h assay time. The microplate provided in this kit has been precoated with anti CLEC4M antibody. Add standard and properly diluted sample into relevant well respectively. After incubation, wash unbound components. Add biotinylated detection antibody. Then, it binds with CLEC4M bound to precoated antibody. Wash unbound components and add HRP-Streptavidin Conjugate (SABC). Wash unbound components again and add TMB substrate solution. Then, TMB was catalyzed by HRP to produce a blue color product that turned yellow after adding a stop solution. Read the O.D. absorbance at 450nm in a microplate reader. Calculate the concentration of CLEC4M in the sample by plotting standard curve. The concentration of the target substance is proportional to the OD450 value.

Catalogue No.: 
EH7460
Alias: 
C-type lectin domain family 4 member M ELISA Kit , CD209 antigen-like protein 1 ELISA Kit , DC-SIGN-related protein ELISA Kit , DC-SIGNR ELISA Kit , Dendritic cell-specific ICAM-3-grabbing non-integrin 2 ELISA Kit , DC-SIGN2 ELISA Kit , Liver/lymph node-specific ICAM-3-grabbing non-integrin ELISA Kit , L-SIGN ELISA Kit , CLEC4M ELISA Kit , CD209L ELISA Kit , CD209L1 ELISA Kit , CD299 ELISA Kit
Gene Name: 
CLEC4M
UniProt ID: 
Q9H2X3
Size Price
48T/96T Inquiry
Dispatch Time: About 3 working days
Contact Us
Product Name
Human CLEC4M(C-type lectin domain family 4 member M) ELISA Kit
Catalogue No.
EH7460
Gene Name
CLEC4M
UniProt ID
Q9H2X3
Alias
C-type lectin domain family 4 member M ELISA Kit , CD209 antigen-like protein 1 ELISA Kit , DC-SIGN-related protein ELISA Kit , DC-SIGNR ELISA Kit , Dendritic cell-specific ICAM-3-grabbing non-integrin 2 ELISA Kit , DC-SIGN2 ELISA Kit , Liver/lymph node-specific ICAM-3-grabbing non-integrin ELISA Kit , L-SIGN ELISA Kit , CLEC4M ELISA Kit , CD209L ELISA Kit , CD209L1 ELISA Kit , CD299 ELISA Kit
Sample Type
Serum, Plasma, Cell Culture Supernatant, cell or tissue lysate, Other liquid samples
Detection Method
Sandwich ELISA, Double Antibody
Detection Wavelength
OD450
Reaction Duration
4 hours
Range
3.125-200ng/ml
Sensitivity
1.875ng/ml
Specificity
Specifically binds with CLEC4M , no obvious cross reaction with other analogues.
Storage
2-8°C(Sealed), Don't cryopreserve.
Kit Components
Kit ComponentsItemSize(48T)Size(96T) Storage Condition for Opened Kit
E001ELISA Microplate(Dismountable) 8×68×12 Put the rest strips into a sealed foil bag with the desiccant. Stored for 1 month at 2-8°C; Stored for 12 month at -20°C
E002Lyophilized Standard 1vial2vial Put the rest standards into a desiccant bag. Stored for 1 month at 2-8°C; Stored for 12 month at -20°C
E003Biotin-labeled Antibody(Concentrated, 100X) 60ul120ul 2-8°C (Avoid Direct Light)
E034HRP-Streptavidin Conjugate(SABC, 100X) 60ul120ul
E024TMB Substrate 5ml10ml
E039Sample Dilution Buffer 10ml20ml 2-8°C
E040Antibody Dilution Buffer 5ml10ml
E049SABC Dilution Buffer 5ml10ml
E026Stop Solution 5ml10ml
E038Wash Buffer(Concentrated, 25X) 15ml30ml
E006Plate Sealer 3 pieces5 pieces
E007Product Description 1 copy1 copy
Typical Standard Curve
STD.(ng/ml)OD-1OD-2Average
00.0860.0880.087
3.1250.1750.1810.178
6.250.2350.2410.238
12.50.3440.3540.349
250.5040.5180.511
500.8520.8760.864
1001.6091.6551.632
2002.0842.1442.114
Precision
ItemSamplenMean (ng/ml)Standard deviationCV (%)
Inter-assay Precision Sample1231
Inter-assay Precision n20202020
Inter-assay Precision Mean (ng/ml)6.223.94101.386.02
Inter-assay Precision Standard deviation0.321.545.190.31
Inter-assay Precision CV(%)5.226.435.125.22


Figures for this product are not available in this catalogue.

Storage
2-8°C(Sealed), Don't cryopreserve.
Dispatch Time
About 3 working days
Ordering & Delivery
How do I place an order?
Use the Inquiry button on this page or write to tekintolga89@gmail.com. Include the catalogue number and the quantity you need.
What is the dispatch time?
In-stock items are dispatched within 1-3 business days. Items that need to be produced take longer; we confirm the date when you order.
Do you ship outside Türkiye?
Shipping is arranged case by case. Contact us with the destination and we will quote carriage and lead time.
Storage & Handling
How should an unopened kit be stored?
At 2-8 °C unless the datasheet says otherwise. Do not freeze a kit that is not marked for freezing.
How long is an opened kit stable?
It depends on the component. The Kit Components table on this page lists the storage condition for each item after opening.
What should I do if the shipment arrives warm?
Photograph the package and contact us the same day. Do not use the kit until we have confirmed it is still within specification.
Assay Questions
Which sample types can I use?
The Sample Type row in the specifications above lists the validated matrices for this product. Other matrices need validation on your side.
My background is too high. What should I check?
The usual causes are insufficient washing, contaminated buffers, or too much detection antibody. Our Protocol pages cover the full troubleshooting sequence.
Can I run fewer wells than the kit provides?
Yes. Dismountable microplates let you use part of a plate and reseal the rest with the desiccant supplied.
Technical Support
Something did not work. What do you need from me?
Send the catalogue number, the lot, your protocol deviations and the raw OD values. That is usually enough to identify the cause.
Do you provide a certificate of analysis?
Yes, per lot. Ask for it with the catalogue number and lot number.

Aradığınızı bulamadınız mı? Tüm SSS sayfasına bakın veya bize yazın.